Inphenix’s Swept Source Laser offer deep penetration, long coherence length and high resolution. Based on Inphenix’s leading Semiconductor Optical Amplifier technology, Inphenix’s frequency swept tunable laser is specifically designed for Swept Source Optical Coherence Tomography (SS-OCT) and Optical Frequency Domain Reflectometry (OFDR) applications. Inphenix’s Swept Sources are available in 1060nm, 1310nm and 1550nm windows and are ideal for OEM integration. We look forward to meeting your standard or customized specifications.
| Center Wavelength(nm) | Sweep Range(nm) | Wavelength Repetition Rate*(kHz) | Coherence Length@-6dB**(mm) | Average Power(mW) | Part Number |
|---|---|---|---|---|---|
| Center Wavelength(nm) | Sweep Range(nm) | Wavelength Repetition Rate*(kHz) | Coherence Length@-6dB**(mm) | Average Power(mW) | Part Number |
| 850+/-20 | 80 - 100 | 16 - 100 | 5-20 | 10 | IPSWM08xx |
| 1050+/-20 | 80 - 100 | 16 - 100 | 5-15 | 10 | IPSWM10xx |
| 1310+/-20 | 80 - 100 | 16 - 100 | 5-20 | 15 | IPSWM13xx |
| 1550+/-20 | 80 - 100 | 16 - 100 | 5-20 | 15 | IPSWM15xx |
Inphenix’s Swept Source Laser marks a significant advancement in the field of optics, offering deep penetration, long coherence length, and high resolution. These features make it an indispensable tool for advanced optical imaging applications. Leveraging Inphenix’s state-of-the-art Semiconductor Optical Amplifier (SOA) technology, the frequency-swept tunable laser is meticulously designed for Swept Source Optical Coherence Tomography (SS-OCT) and Optical Frequency Domain Reflectometry (OFDR). This ensures superior imaging capabilities, allowing researchers to achieve unprecedented clarity and detail in their observations. Leveraging its deep penetration, the Swept Source Laser advances in optics. Designed for SS-OCT and OFDR applications, it ensures superior imaging capability. Designed with the latest swept source laser technology, this tunable solution offers unmatched clarity and depth. Ideal for OEM integration and custom specifications.
Versatility in Wavelength Windows
One of the standout features of Inphenix’s Swept Source Laser is its availability in multiple wavelength windows—1060nm, 1310nm, and 1550nm. This range of wavelengths makes it suitable for a diverse array of applications:
- Medical Imaging: The 1060nm wavelength is ideal for ophthalmic imaging, providing deep tissue penetration with minimal scattering, which is crucial for detailed retinal scans.
- Industrial Inspection: The 1310nm and 1550nm wavelengths are optimal for non-destructive testing and industrial inspection, offering high resolution and the ability to penetrate various materials.
- Biological Research: Different wavelengths cater to various types of tissue imaging, enabling detailed studies in biological research.
Seamless Integration and Customization
Designed for seamless OEM integration, Inphenix’s Swept Source Lasers can be easily incorporated into existing systems. This ease of integration is particularly beneficial for
manufacturers looking to upgrade their imaging systems without extensive modifications. Inphenix also offers customization options, ensuring that their lasers meet the specific needs of each application. Whether you require standard configurations or tailored specifications, Inphenix is committed to providing solutions that align with the highest standards of performance and reliability.
Key Advantages
- Long Coherence Length: Enables deep tissue penetration, making it ideal for medical imaging applications.
- High Resolution: Provides fine structural analysis, essential for detailed imaging and accurate diagnostics.
- Superior Imaging Capabilities: Ensures clear and detailed observations, facilitating advanced research and development.
- Versatility: Multiple wavelength options cater to a wide range of applications, from medical to industrial use.
- Customization: Offers tailored solutions to meet specific research and development needs.
Applications
- Swept Source Optical Coherence Tomography (SS-OCT):
Used extensively in ophthalmology, cardiology, and dermatology for high-resolution, cross-sectional imaging of biological tissues. - Optical Frequency Domain Reflectometry (OFDR):
Employed in the characterization of optical components and fiber networks, providing detailed analysis of reflection and scattering properties. - Material Inspection: Used in industrial settings for non-destructive testing, ensuring the integrity and quality of materials without causing damage.
Collaboration and Support
Inphenix is dedicated to supporting the research and development community by providing precise tools necessary for groundbreaking discoveries in optical coherence tomography. Their team is ready to collaborate with researchers and industry professionals to meet specific
requirements and advance the field of optical imaging. This partnership approach ensures that users receive not only high-quality products but also the technical support and customization needed to achieve their research goals. By choosing Inphenix’s Swept Source
Lasers, researchers and engineers gain access to cutting-edge technology that drives innovation and excellence in optical imaging.
Notes:
* A-scan rate (bidirectional sweeping). Lower A-scan rate swept source also available.
** The coherence length (in air) is the optical path length difference at which the interference fringe visibility drops 50% (or the OCT sensitivity falls 6dB) compared to the zero optical path length difference. The imaging depth is half of the coherence length.
Additional note: 1) k-clock available. 2) Sweep duty cycle is 80 to 100%.